For architects and specifiers

A restored ceiling you can write into a specification

On a renovation the ceiling is usually the largest single surface in the scope and the one with the least interesting answer. Replace the tile, paint the grid, send the old tile to a landfill, and accept that the new plane will not match the rooms you are not touching.

ProCoustic gives you a third option that holds up under review: a coating applied in place, with independent test data behind every performance claim and a three-part specification written to drop into a master specification.

  • Three-part specification
  • Section 09590
  • With or without labor
  • Independent testing
  • Continuing education course
The technical argument

Why a coating on an acoustical tile is a different problem

An acoustical tile is a porous, perforated board. The void is the product. A general purpose coating closes the perforations and bridges the joint between the tile and the suspension grid as it cures, which removes the acoustic performance the tile was specified for and locks the plane shut.

ProCoustic is non-bridging. It coats the tile, the suspension grid, the air diffusers, the return grilles and the speaker plates in a single pass, leaves the perforations open, and leaves every tile free to lift out for access afterward.

That is the property that makes it specifiable rather than a finish decision. Access above the ceiling is unchanged, and the acoustic and surface burning characteristics the design relies on are measured rather than assumed.

Substrates

Acoustical tile, suspension grid, air diffusers, Tectum, acoustical wall panels, baffles and clouds, and metal pan ceilings.

Where it is a continuity argument only

On drywall, conventional coatings perform adequately. ProCoustic belongs there when a drywall soffit splits two acoustical areas and one product across the plane is the point.

Recoatable

The same tile can be recoated again and again, so the specification does not close off the next cycle.

Independent testing

Every performance claim, with the laboratory and the standard

Surface burningFlame spread 25 to 0. Smoke developed 10 to 5. ASTM E84-23c, Steiner Tunnel. NGC Testing Services, Buffalo, New York
Rated assembliesIn a fire-resistance-rated ceiling assembly, confirm the coating with the assembly’s listing before specifying. ProCoat holds no fire-resistance or UL assembly listing.
AcousticNoise reduction coefficient 0.55 to 0.60, a 9 percent improvement. ASTM C423-22 and ASTM E795-16. NGC Testing Services. Standard white formulation
Light reflectance0.80 to 0.902, a 12.75 percent improvement over a new white tile. ASTM E1331-96 and ASTM E903-96. Avian Technologies, Sunapee, New Hampshire
EmissionsCompliant under 0.5 milligrams per cubic meter at 153 grams per square meter. California Department of Public Health Standard Method version 1.2 of 2017. Berkeley Analytical, Richmond, California. Certificate 221104-02
AgingOver 1,000 hours of ultraviolet exposure, ProCoustic outperformed both a new factory coated tile and a tile coated with a high quality latex ceiling paint. ASTM E313. DL Laboratories, New York
Combustion toxicityNon-toxic, and improves the smoke toxicity values of the tile it is applied to. University of Pittsburgh protocol. Anderson Laboratories, Dedham, Massachusetts

All ProCoustic testing was carried out in the standard white formulation. Colorants affect acoustic performance, so other colors may yield different results. Request the current reports before issuing a specification.

Sustainability

What the emissions certificate qualifies for

The California Department of Public Health method behind the Berkeley Analytical certificate is the one most green building programs reference, so a single certificate carries across several of them.

LEED version 4 and 4.1

Building Design and Construction, Interior Design and Construction, and Residential Building Design and Construction Multifamily. Restoration also contributes toward credit for reusing existing structures.

Green Globes

American National Standards Institute and Green Building Initiative 01-2019 assessment protocol.

CalGreen

The California Department of Public Health method is the California Specification 01350 that CalGreen references.

750 millionSquare feet of ceiling tile kept out of landfills since 1983
0.902Light reflectance after coating, against 0.80 for a new white tile
0 to 5Flame spread and smoke developed, from 25 and 10 before coating
What to ask for

The specification, and how it is written

Section 09590, two versions

A product and installation service specification, and a system specification covering material alone. Which one you issue depends on whether labor sits inside the ProCoat scope or with the contractor.

Guide specifications for the rest of the range

ProVinyl and ProWall have their own guide specifications. ProWall covers resurfacing existing fiber-reinforced plastic walls, and ProVinyl covers vinyl-faced tiles in kitchens and food preparation areas as an installed turnkey system.

Each specification states what the coating has to achieve rather than only what it is, which is what lets it survive a value engineering review without being substituted for a general purpose product.

Where it has been specified

It has been through this review before

Written into a grocery specification

An architect wrote ProCoustic into the Kroger specification in 2015, and it has stayed in the remodel scope since.

A forty-one location program

One specification held across forty-one J.C. Penney locations in twenty-nine states over seven months, without closing a store.

Institutional work

Mississippi Valley State University, and transportation and healthcare environments where the ceiling could not come down.

Continuing education

A course, or an hour in your office

ProCoat holds an approved American Institute of Architects course on acoustical ceiling restoration, and is a member of AEC Daily. If a lunch and learn is more useful than a course, ProCoat will come to the office and bring coated and uncoated samples so the non-bridging behavior can be handled rather than described.

A demonstration on the actual building is the other option. Around a hundred square feet, a vestibule or part of a corridor, coated so the client sees the result on their own ceiling before anything is specified.